초록

BACKGROUND: Angiography-based fractional flow reserve (FFR) techniques offer wire-free alternatives but often require manual segmentation and 3-dimensional reconstruction. Although an artificial intelligence-driven approach automates these steps, validation remains limited. This study investigated the diagnostic performance of an artificial intelligence-driven angiographybased FFR (medipixel FFR [MPFFR]), compared with quantitative flow ratio (QFR) in predicting functionally significant coronary artery stenosis defined by FFR <= 0.80. METHODS: A total of 599 vessels from 452 patients who underwent clinically indicated FFR measurement were prospectively enrolled from 5 university hospitals in Korea. MPFFR used automated processes in frame selection, artificial intelligence contour detection, corresponding points matching, 3-dimensional reconstruction, and analytical hemodynamic modeling. The primary end point was diagnostic accuracy for detecting FFR <= 0.80. Secondary end points were target vessel failure (composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization) at 2years. RESULTS: Mean analysis time of MPFFR was 12.5 +/- 1.7 seconds and manual correction was needed in 32 vessels (5.3%). MPFFR showed similar diagnostic performance with QFR (correlation with FFR; MPFFR versus QFR: R=0.885 versus R=0.860, P for comparison=0.011; area under the curve to predict FFR <= 0.80; 0.949 versus 0.953, P for comparison=0.631). At a median follow-up of 2years (interquartile range, 1.6-2.6years), patients with MPFFR <= 0.80 had higher risk of target vessel failure than those with MPFFR >0.80 (4.5% versus 0.8%; adjusted hazard ratio, 5.94 [95% CI, 1.27-27.91]; P=0.024). C-index to predict target vessel failure was comparable between MPFFR and QFR (0.770 versus 0.753, P for comparison=0.469). CONCLUSIONS: In this multicenter registry, an artificial intelligence-driven angiography-based FFR demonstrated comparable diagnostic accuracy with QFR in identifying functionally significant stenosis, and similar prognostic ability with QFR in terms of target vessel failure at 2years.

키워드

artificial intelligence; fractional flow reserve; percutaneous coronary intervention; prognosis; PROGNOSTIC IMPLICATIONS; DIAGNOSTIC-ACCURACY; RATIO
제목
Artificial Intelligence-Driven Angiographic Quantification of Fractional Flow Reserve: Proof-of-Concept Validation Study
저자
Lee, Seung Hun; Gim, Dong Hyun; Hwang, Doyeon; Kim, Hyun Kuk; Cho, Hyun; Kim, Sung Eun; Cho, Sung Woo; Choi, Ki Hong; Park, Taek Kyu; Yang, Jeong Hoon; Song, Young Bin; Doh, Joon-Hyung; Nam, Chang-Wook; Hahn, Joo-Yong; Koo, Bon-Kwon; Choi, Seung-Hyuk; Gwon, Hyeon-Cheol; Yoon, Hyuck-Jun; Lee, Joo Myoung
DOI
10.1161/JAHA.125.049331
발행일
2026-09-01
유형
Article
저널명
Journal of the American Heart Association
권
15
호
17