상세 보기
Diffusion-weighted magnetic resonance imaging using different <i>b</i>-value combinations for the evaluation of treatment results after volumetric MR-guided high-intensity focused ultrasound ablation of uterine fibroids
- Ikink, Marlijne E.;
- Voogt, Marianne J.;
- van den Bosch, Maurice A. A. J.;
- Nijenhuis, Robbert J.;
- Keserci, Bilgin;
- 외 3명
WEB OF SCIENCE
25SCOPUS
34초록
To assess the value of diffusion-weighted magnetic resonance imaging (DWI) and apparent diffusion coefficient (ADC) mapping using different b-value combinations for treatment evaluation after magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) of uterine fibroids. Fifty-six patients with 67 uterine fibroids were treated with volumetric MR-HIFU. Pre-treatment and post-treatment images were obtained using contrast-enhanced T1-weighted MRI (CE-T1WI) and DWI using b = 0, 200, 400, 600, 800 s/mm(2). ADC maps were generated using subsets of b-values to investigate the effects of tissue ablation on water diffusion and perfusion in fibroids treated with MR-HIFU. Four combinations of b-values were used: (1) all b-values; (2) b = 0, 200 s/mm(2); (3) b = 400, 600, 800 s/mm(2); and (4) b = 0, 800 s/mm(2). Using the lowest b-values (0 and 200 s/mm(2)), the mean ADC value in the ablated tissue reduced significantly (p < 0.001) compared with baseline. Calculating the ADC value with the highest b-values (400, 600, 800 s/mm(2)), the ADC increased significantly (p < 0.001) post-treatment. ADC maps calculated with the lowest b-values resulted in the best visual agreement of non-perfused fibroid tissue detected on CE images. Other b-value combinations and normal myometrium showed no difference in ADC after MR-HIFU treatment. A decrease in contrast agent uptake within the ablated region on CE-T1WI was correlated to a significantly decreased ADC when b = 0 and 200 s/mm(2) were used. aEuro cent DWI could be useful for treatment evaluation after MR-HIFU of uterine fibroids aEuro cent The ADC in fibroid tissue is influenced by the choice of b- values aEuro cent Low b-values seem the best choice to emphasise perfusion effects after MR-HIFU.
키워드
- 제목
- Diffusion-weighted magnetic resonance imaging using different <i>b</i>-value combinations for the evaluation of treatment results after volumetric MR-guided high-intensity focused ultrasound ablation of uterine fibroids
- 저자
- Ikink, Marlijne E.; Voogt, Marianne J.; van den Bosch, Maurice A. A. J.; Nijenhuis, Robbert J.; Keserci, Bilgin; Kim, Young-sun; Vincken, Koen L.; Bartels, Lambertus W.
- 발행일
- 2014-09
- 유형
- Article
- 권
- 24
- 호
- 9
- 페이지
- 2118 ~ 2127
- 언어
- ENG
- 출판사
- Springer Verlag
- 발행국가
- 미국
- 분량
- 10 페이지
- ISSN
- E 1432-1084
P 0938-7994