Transjugular liver biopsy: modified Ross transseptal needle versus Quick-core biopsy needle

  • Choo, SW; 
  • Do, YS; 
  • Park, KB; 
  • Kim, SH; 
  • Han, YH; 
  • 외 1명
Citations

WEB OF SCIENCE

18
Citations

SCOPUS

20

초록

Background: We evaluated the differences in sample adequacy and safety between a transseptal needle and Quick-core biopsy needle for transjugular liver biopsy. Methods: Eighteen consecutive patients who had a bleeding diatheses and/or ascites underwent transjugular liver biopsy using a transseptal needle (II patients) and Quick-core biopsy needle (seven patients), The length of the specimens was measured before fixation. A pathologist reviewed histologic slides for sample adequacy and pathologic diagnoses. Clinical records were reviewed for complication. Results: In all patients, liver biopsy was successful. A total of 45 specimens were obtained, with an average of 2.5 passes per patient. The length of specimen was significantly longer with the Quick-core biopsy needle than with the transseptal needle (p < 0.05). Biopsied tissue was fragmented in 17 of 25 specimens with the transseptal needle but not fragmented in any specimen with the Quick-core biopsy needle. All specimens were determined to be adequate except one with the transseptal needle. There was no early or delayed complication in any patient. Conclusion: Transjugular liver biopsy is a safe and effective procedure without any significant difference in complication and adequacy when using a transseptal needle or Quick-core biopsy needle. Larger specimens can be obtained without tissue fragmentation with the Quick-core biopsy needle.

키워드

liver disease, biopsy; interventional procedures; transjugular biopsy; EXPERIENCE
제목
Transjugular liver biopsy: modified Ross transseptal needle versus Quick-core biopsy needle
저자
Choo, SW; Do, YS; Park, KB; Kim, SH; Han, YH; Choo, IW
DOI
10.1007/s002610000043
발행일
2000-09
유형
Article
저널명
Abdominal Imaging
권
25
호
5
페이지
483 ~ 485