Acute Outflow Obstruction of Hepatic Veins in Rabbits Quantitative Analysis of Hepatic Perfusion With Contrast-Enhanced Sonography

  • Kim, Kyoung Won; 
  • Kim, Pyo Nyun; 
  • Shin, Ji Hoon; 
  • Shin, Dong Ho; 
  • Jeong, Woo Kyoung; 
  • 외 7명
Citations

WEB OF SCIENCE

6
Citations

SCOPUS

7

초록

Objectives-To compare time-enhancement curve parameters of contrast-enhanced sonography in acute partial hepatic venous outflow obstruction with those of a baseline study. Methods-Contrast-enhanced sonography was performed in 11 rabbits with bolus administration of a sulfur hexafluoride contrast agent (0.1 mL/kg). After baseline scanning for 3 minutes, a 5.3F balloon catheter was placed into the left hepatic vein. Obstruction was artificially induced by 0.4-mL balloon inflation, and sonography was repeatedly performed thereafter. On images stored with 1-second intervals, 2 x 2-mm regions of interest were placed, and mean luminosity was measured. Time-enhancement curves were plotted, and contrast arrival times, peak enhancement values, peak enhancement times, 50% wash-out times, and 3-minute wash-out rates were obtained. Paired t tests were performed to evaluate the significance of differences in the parameters between baseline and obstruction. Results-On baseline sonography, the median contrast arrival time, peak enhancement value, peak enhancement time, 50% wash-out time, and 3-minute wash-out rate were 6 (range, 4-8; mean SD, 5.9 +/- 1.2) seconds, 188.5 (104.7-209.5; 178.4 +/- 33.1) arbitrary units, 19 (14-27; 19.8 +/- 4.1) seconds, 75 (60-101; 78.2 +/- 13.9) seconds, and 89.7% (81.3%-95.1%; 88.4% +/- 4.9%), respectively. With obstruction, those values were 7(5-12; 6.9 +/- 2.3) seconds, 202.8 (98.2-215.1; 186.0 +/- 39.3) arbitrary units, 31 (17-59; 32 +/- 11.6) seconds, 101 (47-136; 96.2 +/- 23.6) seconds, and 79.2% (66.2%-88.8%; 79.1% +/- 7.6%). Compared with baseline, the peak enhancement time was significantly delayed from 19 to 31 seconds (P = .0027), 50% wash-out time significantly delayed from 75 to 101 seconds (P = .0209), and 3-minute wash-out rate significantly decreased from 89.7% to 79.2% (P < .0001) with obstruction, but there were no significant differences in contrast arrival times and peak enhancement values (P = .0756 and .2179). Conclusions-Contrast-enhanced sonography can provide quantitative assessment of microbubble congestion in partial hepatic venous outflow obstruction. The peak enhancement time and 50% wash-out time are delayed and 3-minute wash-out rate is decreased in rabbits with artificially induced obstruction compared with a baseline study.

키워드

animal study; contrast-enhanced sonography; hepatic venous obstruction; perfusion study; DONOR LIVER-TRANSPLANTATION; RIGHT LOBE GRAFT; COMPUTED-TOMOGRAPHY PERFUSION; DOPPLER WAVE-FORM; VENOUS CONGESTION; TRANSIT-TIME; ENDOVASCULAR TREATMENT; BALLOON ANGIOPLASTY; PORCINE MODEL; CT
제목
Acute Outflow Obstruction of Hepatic Veins in Rabbits Quantitative Analysis of Hepatic Perfusion With Contrast-Enhanced Sonography
저자
Kim, Kyoung Won; Kim, Pyo Nyun; Shin, Ji Hoon; Shin, Dong Ho; Jeong, Woo Kyoung; Won, Hyung Jin; Shin, Yong Moon; Lee, Won Jae; Lee, Moon Gyu; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu
DOI
10.7863/jum.2011.30.5.635
발행일
2011-05
유형
Article
저널명
Journal of Ultrasound in Medicine
권
30
호
5
페이지
635 ~ 642