In vitro evaluation of bacterial leakage resistance of an ultrasonically placed mineral trioxide aggregate orthograde apical plug in teeth with wide open apexes: a preliminary study

  • Kim, Un-Sung; 
  • Shin, Su-Jung; 
  • Chang, Seok Woo; 
  • Yoo, Hyun-Mi; 
  • Oh, Tae-Seok; 
  • 외 1명
Citations

WEB OF SCIENCE

21
Citations

SCOPUS

26

초록

Objective. The purpose of this study was to compare the sealing ability of an ultrasonically placed orthograde mineral trioxide aggregate (MTA) apical plug in open apices. Study design. Thirty extracted human maxillary incisors were used. Experimental teeth were instrumented up to #100 file at the apex, and the 5 mm MTA apical barrier was placed with (group A; n = 11) or without (group B; n = 11) ultrasonic activation. Eight teeth served as control group. Bacterial leakage was assessed daily for 180 days using a double-chamber bacterial leakage model with Enterococcus faecalis. The results were analyzed with Fisher exact test. Results. After 60 days, the ratio of leaked samples showed significant difference between groups A (2 out of 10) and B (8 out of 11) (P < .05). The mean time elapsed before leakage showed significant difference between groups A (158 days) and B (23 days) (P < .05). Conclusions. Ultrasonically placed orthograde MTA apical plugs were effective at delaying bacterial leakage. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107: e52-e56)

키워드

END FILLING MATERIALS; CALCIUM HYDROXIDE; SEALING ABILITY; APEXIFICATION; MTA; FRACTURE; MODEL
제목
In vitro evaluation of bacterial leakage resistance of an ultrasonically placed mineral trioxide aggregate orthograde apical plug in teeth with wide open apexes: a preliminary study
저자
Kim, Un-Sung; Shin, Su-Jung; Chang, Seok Woo; Yoo, Hyun-Mi; Oh, Tae-Seok; Park, Dong Sung
DOI
10.1016/j.tripleo.2008.12.049
발행일
2009-04
유형
Article
저널명
Oral Surgery Oral Medicine Oral Pathology Oral Radiology
권
107
호
4
페이지
E52 ~ E56