Purpose: To evaluate the energy efficiency of differently sized volumetric ablations in MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of uterine fibroids. Materials and methods: This study was approved by the institutional review board and informed consent was obtained from all participants. Ten symptomatic uterine fibroids (mean diameter 8.9 cm) in 10 women (mean age 42.2) were treated by volumetric MR-HIFU ablation under binary feedback control. The energy efficiency (mm(3)/J) of each sonication was calculated as the volume of lethal thermal dose (240 equivalent minutes at 43 degrees C) per unit acoustic energy applied. Operator-controllable parameters and signal intensity ratio of uterine fibroid to skeletal muscle on T2-weighted MR images were tested with univariate and multivariate analyses to discern which parameters significantly correlated with the ablation energy efficiency. Results: We analyzed a total of 236 sonications. The energy efficiency of the ablations was 0.42 +/- 0.25 mm(3)/J (range 0.004-1.18) with energy efficiency improving with the treatment cell size (4 mm, 0.06 +/- 0.06 mm(3)/J; 8 mm, 0.29 +/- 0.12 mm(3)/J; 12 mm, 0.58 +/- 0.18 mm(3)/J; 16 mm, 0.91 +/- 0.17 mm(3)/J). Treatment cell size (r = 0.814, p < 0.001), distance of ultrasound propagation (r = -0.151, p = 0.020), sonication frequency (1.2 or 1.45 MHz; p < 0.001), and signal intensity ratio (r = -0.205, p = 0.002) proved to be significant by univariate analysis, while multivariate analysis revealed treatment cell size (B = 0.075, p < 0.001), US propagation distance (B = -6.928, p < 0.001), and signal intensity ratio (B = -0.024, p = 0.001) to be independently significant. Conclusion: Energy efficiency in volumetric MR-HIFU ablation of uterine fibroids improves with increased treatment cell size, independent of other significant contributors such as distance of ultrasound propagation or signal intensity of the tumor on T2-weighted MR imaging. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

키워드

High-intensity focused ultrasound; Uterine fibroid; Energy efficiency; Volumetric ablation technique; Treatment speed; FOCUSED ULTRASOUND SURGERY; LEIOMYOMAS; TISSUES; ATTENUATION; THERAPY
제목
Volumetric MR-HIFU ablation of uterine fibroids: Role of treatment cell size in the improvement of energy efficiency
저자
Kim, Young-sun; Keserci, Bilgin; Partanen, Ari; Rhim, Hyunchul; Lim, Hyo K.; Park, Min Jung; Kohler, Max O.
DOI
10.1016/j.ejrad.2011.09.005
발행일
2012-11
유형
Article
저널명
European Journal of Radiology
권
81
호
11
페이지
3652 ~ 3659