Evaluation of Factors Affecting Illumination Intensity in Lightwand Endotracheal Intubation

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

2

초록

Background/Aim: A lightwand is a stylet with a light bulb at its tip that can be used to guide intubation by confirming the illumination through the anterior neck. We aimed to determine the factors affecting the illumination intensity during lightwand endotracheal intubation. Patients and Methods: We retrospectively collected data from 180 patients who underwent lightwand endotracheal intubation. We recorded illumination intensity on a 5-point scale. The patients were categorized into weak (score <3) and bright (score >= 3) groups based on the illumination intensity scale score. Results: A total of 176 patients were analyzed, of whom 125 (71.1%) were enrolled in the bright group, and 51 (29.0%) were enrolled in the weak group. Multivariable logistic regression analysis revealed that an increased body mass index (BMI) and mask ventilation grade were associated with light intensity. For mask ventilation, moderate vs. easy (p=0.010) and difficult vs. easy (p=0.008) were associated with the weak group. Receiver operating characteristic curve analysis showed that BMI >= 24.6 kg/m(2) was correlated with the weak group. Conclusion: BMI >= 24.6 kg/m(2) or mask ventilation grade above moderate indicates increased odds of weak illumination intensity in lightwand intubation. Pre-intubation examination of these factors helps increase the chances of successful intubation.

키워드

Body mass index; endotracheal; intubation; lightwand; neck; TRACHEAL INTUBATION; AIRWAY; LARYNGOSCOPY; MANAGEMENT
제목
Evaluation of Factors Affecting Illumination Intensity in Lightwand Endotracheal Intubation
저자
Hong, Kwan young; Lee, Ja eun; Hwang, Hyun ji; Sim, Woo seog; Park, Hue jung; Lee, Jin young
DOI
10.21873/invivo.13464
발행일
2024-01
유형
Article
저널명
In Vivo
권
38
호
1
페이지
490 ~ 495