상세 보기
초록
Purpose Cortical biopsy is the cornerstone to reveal a cause of unexplained dysfunction of the kidney transplant. Nevertheless, only a few studies have reported the biopsy technique with its performance. We described a novel technique of ultrasound (US)-guided kidney transplant biopsy using cortex-only view and analyzed its diagnostic efficacy and safety. Materials and methods Between January 2014 and December 2016, a consecutive series of 188 patients who underwent US-guided kidney transplant biopsy using cortex-only view by an experienced radiologist were evaluated (mean age, 46.1 +/- 12.5 years; range, 21-79 years). Biopsy time, biopsy distance, biopsy core number, and glomerular number per patient were recorded. Successful biopsy (e.g., adequate, 10 or more glomeruli; marginal, 7-9 glomeruli) and complication rates were investigated, using Banff criteria and Clavien-Dindo classification, respectively. Results Mean biopsy time, distance, and core number were 20.6 +/- 6.7 min (range, 10-44 min), 3.2 +/- 0.7 cm (range, 2.1-5.4 cm), and 1.9 +/- 0.3 (range, 1.0-3.0), respectively. Mean glomerular number per patient was 20.4 +/- 10.0 (range, 0-54). Adequate and marginal biopsy rates were 87.2% (164/188) and 95.2% (179/188), respectively. There was no major complication requiring treatment (no patient with Clavien-Dindo grade 2 or greater complication), while there were self-limiting minor complications in 5 patients (overall complication rate, 2.7%). Conclusion US-guided biopsy using cortex-only view is feasible and safe in sampling cortical tissues of kidney transplant.
키워드
- 제목
- Diagnostic efficacy and safety of ultrasound-guided kidney transplant biopsy using cortex-only view: a retrospective single-center study
- 저자
- Shin, Jaeseung; Park, Sung Yoon
- 발행일
- 2019-10
- 유형
- Article
- 권
- 29
- 호
- 10
- 페이지
- 5272 ~ 5279
- 언어
- ENG
- 출판사
- Springer Verlag
- 발행국가
- 미국
- 분량
- 8 페이지
- ISSN
- E 1432-1084
P 0938-7994