The purpose of this study was to measure the radiation exposure to operator and patient during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures and to calculate the allowable number of cases per year. We carried out 9 electrophysiology studies, 40 radiofrequency catheter ablation and 11 cardiac device implantation procedures. To measure occupational radiation dose and dose-area product (DAP), 13 photoluminescence glass dosimeters were placed at eyes (inside and outside lead glass), thyroids (inside and outside thyroid collar), chest (inside and outside lead apron), wrists, genital of the operator (inside lead apron), and 6 of photoluminescence glass dosimeters were placed at eyes, thyroids, chest and genital of the patient. Exposure time and DAP values were 11.7 +/- 11.8min and 23.2 +/- 26.2Gycm(2) for electrophysiology study; 36.5 +/- 42.1min and 822.4 +/- 125.5Gycm(2) for radiofrequency catheter ablation; 16.2 +/- 9.3min and 27.8 +/- 16.5Gycm(2) for cardiac device implantation procedure, prospectively. 4591 electrophysiology studies can be conducted within the occupational exposure limit for the eyes (150mSv), and 658-electrophysiology studies with radiofrequency catheter ablation can be carried out within the occupational exposure limit for the hands (500mSv). 1654 cardiac device implantation procedure can be conducted within the occupational exposure limit for the eyes (150mSv). The amounts of the operator and patient's radiation exposure were comparatively small. So, electrophysiology study, radio frequency catheter ablation and cardiac device implantation procedures are safe when performed with modern equipment and optimized protective radiation protect equipment.

키워드

radiation exposure; electrophysiology study; catheter ablation; photoluminescence glass dosimeters; SUPRAVENTRICULAR TACHYCARDIA; INTERVENTIONAL PROCEDURES; INVASIVE CARDIOLOGY; FLUOROSCOPY; DOSIMETRY; SKIN; SEMICONDUCTORS; LUMINESCENCE; INSULATORS; RISK
제목
Radiation exposure to operator and patients during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures
저자
Lee, C. H.; Cho, J. H.; Park, S. J.; Kim, J. S.; On, Y. K.; Huh, J.
DOI
10.1080/10420150.2015.1108318
발행일
2015-10-03
유형
Article
저널명
Radiation Effects and Defects in Solids
권
170
호
10
페이지
787 ~ 795