Aortic Valve Replacement With Carpentier-Edwards: Hemodynamic Outcomes for the 19-mm Valve

Citations

WEB OF SCIENCE

9
Citations

SCOPUS

11

초록

Background. To compare hemodynamic performance and clinical outcomes after aortic valve replacement for aortic stenosis with the 19-mm Carpentier-Edwards pericardial bioprosthesis versus larger valves. Methods. Between January 1998 and December 2013, 447 consecutive patients underwent aortic valve replacement for aortic stenosis with the Carpentier-Edwards Perimount (n = 61) or Magna bioprostheses (n = 386). Based on the implanted valve size, the patients were classified into three groups: a 19-mm group (n = 54), a 21-mm group (n = 154), and a 23-mm to 27-mm group (n = 239). The in vivo effective orifice area index was measured by transthoracic echocardiography 12 months after operation (n = 331). The mean follow-up time was 4.9 +/- 3.5 (maximum 15.4) years. Results. There were three early deaths (0.7%). At 10 years, overall survival (84.1%) was unaffected by patient-prosthesis mismatch (18.7%, 62 patients), and freedom from structural valve deterioration and endocarditis was 100% and 97.1%, respectively. Although the 19-mm group was significantly older and had a higher incidence of patient-prosthesis mismatch (n = 14, 30.4%), there were no significant differences in early outcomes, overall survival, cardiac-related mortality, or serial reduction of left ventricular mass index in comparison with patients with a larger bioprostheses. Independent risk factors for all-cause mortality were age, male gender, combined coronary artery bypass graft, and low hemoglobin level. Conclusion. The Carpentier-Edwards pericardial bioprosthesis appears to be associated with acceptable clinical outcomes and hemodynamic profile. (C) 2016 by The Society of Thoracic Surgeons

키워드

PROSTHESIS-PATIENT MISMATCH; PERIMOUNT MAGNA BIOPROSTHESIS; VENTRICULAR MASS REGRESSION; CESA PORCINE BIOPROSTHESES; STENTLESS PRIMA-EDWARDS; HAND SEWN ALLOGRAFTS; TERM MORTALITY; IMPACT; POSITION; PERFORMANCE
제목
Aortic Valve Replacement With Carpentier-Edwards: Hemodynamic Outcomes for the 19-mm Valve
저자
You, Ji Hoon; Jeong, Dong Seop; Sung, Kiick; Kim, Wook Sung; Carriere, K. C.; Lee, Young Tak; Park, Pyo Won
DOI
10.1016/j.athoracsur.2015.11.016
발행일
2016-06
유형
Article
저널명
Annals of Thoracic Surgery
권
101
호
6
페이지
2209 ~ 2216