상세 보기
초록
In rehabilitation, the Fugl-Meyer assessment (FMA) is a typical clinical instrument to assess upper-extremity motor function of stroke patients, but it cannot measure fine changes of motor function (both in recovery and deterioration) due to its limited sensitivity. This paper introduces a sensor-based automated FMA system that addresses this limitation with a continuous rating algorithm. The system consists of a depth sensor (Kinect V2) and an algorithm to rate the continuous FM scale based on fuzzy inference. Using a binary logic based classification method developed from a linguistic scoring guideline of FMA, we designed fuzzy input/output variables, fuzzy rules, membership functions, and a defuzzification method for several representative FMA tests. A pilot trial with nine stroke patients was performed to test the feasibility of the proposed approach. The continuous FM scale from the proposed algorithm exhibited a high correlation with the clinician rated scores and the results showed the possibility of more sensitive upper-extremity motor function assessment.
키워드
- 제목
- Proof-of-Concept of a Sensor-Based Evaluation Method for Better Sensitivity of Upper-Extremity Motor Function Assessment
- 저자
- Lee, Seung-Hee; Hwang, Ye-Ji; Lee, Hwang-Jae; Kim, Yun-Hee; Ogrinc, Matjaz; Burdet, Etienne; Kim, Jong-Hyun
- 발행일
- 2021-09
- 유형
- Article
- 저널명
- Sensors
- 권
- 21
- 호
- 17
- 언어
- ENG
- 출판사
- Multidisciplinary Digital Publishing Institute (MDPI)
- 발행국가
- 스위스
- ISSN
- E 1424-8220