상세 보기
Efficacy of Computer-Aided Detection System and Thin-Slab Maximum Intensity Projection Technique in the Detection of Pulmonary Nodules in Patients With Resected Metastases
- Park, Eun-Ah;
- Goo, Jin Mo;
- Lee, Jeong Won;
- Kang, Chang Hyun;
- Lee, Hyun Ju;
- ... Lee, Ho Yun;
- 외 3명
WEB OF SCIENCE
36SCOPUS
42초록
Objectives: To evaluate the efficacy of the computer-aided detection (CAD) system and thin-slab maximum intensity projection (MIP) technique in the detection of pulmonary nodules at multidetector computed tomography (CT) in patients who underwent metastatectomy. Materials and Methods: This retrospective study was approved by the institutional review board and patients' informed consent was waived. Forty-nine consecutive patients who underwent pulmonary metastatectomy were enrolled. Four chest radiologists analyzed preoperative 1-mm section CT images and recorded the locus of each nodule candidate. Afterward, they reevaluated the images once using CAD software and once with thin-slab MIP given the results of 1-mm section CT alone. The reference standard for nodule presence was established by a consensus panel and pathologic records for malignant nodules. Results: A total of 514 nodules were identified by a consensus panel. Of 212 nodules surgically removed, 121 nodules were malignant. The sensitivity of each observer in detecting malignant nodules with thin-section CT scans alone was 91%, 88%, 87%, and 86% for observers A- to D, respectively. With CAD, sensitivity increased significantly to 95%, 95%, 94%, and 95% (P<0.05 for observer B-D), and using MIP increased to 94%, 96%, 91%, and 92% (P<0.05 for observer B-D), respectively. There were no significant differences in sensitivity between CAD and MIP for the detection of malignant nodules. The average number of false-positive findings per patient was 0.8 with thin-section CT alone, 1.1 with CAD, and 1.4 with MIP. Conclusions: In candidates for metastatectomy, reading with the aid of either CAD or MIP significantly improved the detection of malignant nodules compared with using thin-section CT alone.
키워드
- 제목
- Efficacy of Computer-Aided Detection System and Thin-Slab Maximum Intensity Projection Technique in the Detection of Pulmonary Nodules in Patients With Resected Metastases
- 저자
- Park, Eun-Ah; Goo, Jin Mo; Lee, Jeong Won; Kang, Chang Hyun; Lee, Hyun Ju; Lee, Chang Hyun; Park, Chang Min; Lee, Ho Yun; Im, Jung-Gi
- 발행일
- 2009-02
- 유형
- Article
- 권
- 44
- 호
- 2
- 페이지
- 105 ~ 113
- 언어
- ENG
- 출판사
- LIPPINCOTT WILLIAMS & WILKINS
- 발행국가
- 미국
- 분량
- 9 페이지
- ISSN
- E 1536-0210
P 0020-9996