The influence of liquid crystal display monitors on observer performance for the detection of interstitial lung markings on both storage phosphor and flat-panel-detector chest radiography
- Sung, Yon Mi;
- Chung, Myung Jin;
- Lee, Kyung Soo;
- Choe, Bong-Keun
WEB OF SCIENCE
2SCOPUS
2초록
Purpose: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode ray tube (CRT) monitor in the detection of interstitial lung markings using a silicon flat-panel-detector direct radiography (DR) and storage phosphor computed radiography (CR) in a clinical setting. Materials and methods: We displayed 39 sets of posteroanterior chest radiographs from the patients who were suspected of interstitial lung disease. Each sets consisted of DR, CR and thin-section CT as the reference standard. Image identities were masked, randomly sorted, and displayed on both five mega pixel (2048 x 2560 x 8 bits) LCD and CRT monitors. Ten radiologists independently rated their confidence in detection for the presence of linear opacities in the four fields of the lungs; right upper, left upper, right lower, and left lower quadrant. Performance of a total 6240 (39 sets x 2 detector systems x 2 monitor system x 4 fields x 10 observers) observations was analyzed by multi-reader multi-case receiver operating characteristic (ROC) analysis. Differences between monitor systems in combinations of detector systems were compared using ANOVA and paired-samples t-test. Results: Area under curves (AUC) for the presence of linear opacities measured by ROC analysis was higher on the LCDs than CRTs without statistical significance (p = 0.082). AUC was significantly higher on the DR systems than CR systems (p = 0.006). AUC was significantly higher on the LCDs than CRTs for DR systems (p = 0.039) but not different for CR systems (p = 0.301). Conclusion: In clinical conditions, performance of the LCD monitor appears to be better for detecting interstitial lung markings when interfaced with DR systems. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
키워드
- 제목
- The influence of liquid crystal display monitors on observer performance for the detection of interstitial lung markings on both storage phosphor and flat-panel-detector chest radiography
- 저자
- Sung, Yon Mi; Chung, Myung Jin; Lee, Kyung Soo; Choe, Bong-Keun
- 발행일
- 2010-04
- 유형
- Article
- 권
- 74
- 호
- 1
- 페이지
- 275 ~ 279
- 언어
- ENG
- 출판사
- Elsevier BV
- 발행국가
- 아일랜드
- 분량
- 5 페이지
- ISSN
- E 1872-7727
P 0720-048X