상세 보기
Breast Imaging Reporting and Data System Category 3 Lesions Detected on Whole-Breast Screening Ultrasound
- Nam, Sang Yu;
- Ko, Eun Young;
- Han, Boo-Kyung;
- Shin, Jung Hee;
- Ko, Eun Sook;
- ... Hahn, Soo Yeon
WEB OF SCIENCE
22SCOPUS
23초록
Purpose: This study assessed the incidence and cancer rate of probably benign lesions detected on bilateral whole-breast screening ultrasound (US), which corresponded to US Breast Imaging Reporting and Data System (BI-RADS) category 3, and evaluated the proper management of those lesions. Methods: This study was approved by the Institutional Review Board in our institution, which waived informed patient consent. We retrospectively reviewed US images of 1,666 patients who underwent bilateral whole-breast screening US as a supplemental screening test to negative screening mammography or screening US only. The incidence, clinical course, and cancer rate of screening US detected probably benign lesions corresponding to US BI-RADS category 3 were investigated, and the size and multiplicity of screening US-detected category 3 lesions were evaluated. Results: Probably benign lesions corresponding to US BI-RADS category 3 were detected in 689 of 1,666 patients (41.4%) who underwent screening US. Among them, 653 had follow-up US images for at least 24 months, and among these 653, 190 (29.1%) had multiple bilateral category 3 lesion. Moreover, 539 of 1,666 patients (32.4%) had lesions 1 cm in size and 114 of 1,666 (6.8%) had lesions >1 cm (median, 0.82 cm; range, 0.34.2 cm). Four of the 653 patients (0.6%) showed suspicious interval changes and were categorized into BI-RADS category 4. Biopsy analysis confirmed only one lesion as invasive ductal carcinoma at the 6-month follow-up; another lesion was an intraductal papilloma and the remaining two were fibroadenomas. Overall cancer rate of the screening US-detected BI-RADS category 3 lesions was 0.2%. Conclusion: The incidence of category 3 lesions detected on screening US only was very high, but the cancer rate was very low. Therefore, in an average-risk population, routine screening US is preferable over short-term followup for BI-RADS category 3 lesions detected on whole-breast screening US.
키워드
- 제목
- Breast Imaging Reporting and Data System Category 3 Lesions Detected on Whole-Breast Screening Ultrasound
- 저자
- Nam, Sang Yu; Ko, Eun Young; Han, Boo-Kyung; Shin, Jung Hee; Ko, Eun Sook; Hahn, Soo Yeon
- 발행일
- 2016-09
- 유형
- Article
- 권
- 19
- 호
- 3
- 페이지
- 301 ~ 307
- 언어
- ENG
- 출판사
- 한국유방암학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- E 2092-9900
P 1738-6756