Digital Subtraction Cystography for Detection of Communicating Holes of Spinal Extradural Arachnoid Cysts

  • Gu, Kyowon; 
  • Kwon, Jong Won; 
  • Kim, Eun-Sang
Citations

WEB OF SCIENCE

12
Citations

SCOPUS

15

초록

Objective: The purpose of this study was to demonstrate the usefulness of digital subtraction cystography to identify communicating holes between a spinal extradural arachnoid cyst (SEAC) and the subarachnoid space prior to cyst removal and hole closure. Materials and Methods: Six patients with SEAC were enrolled in this retrospective study. Digital subtraction cystography and subsequent CT myelography were performed for every patient. The presence and location of the communicating holes on cystography were documented. We evaluated the MRI characteristics of the cysts, including location, size, and associated spinal cord compression; furthermore, we reviewed cystographic images, CT myelograms, procedural reports, and medical records for analysis. If surgery was performed after cystography, intraoperative findings were compared with preoperative cystography. Results: The Location of the communicating hole between the arachnoid cyst and the subarachnoid space was identified by digital subtraction cystography in all cases (n = 6). Surgical resection of SEAC was performed in 4 patients, and intraoperative location of the communicating hole exactly corresponded to the preoperative identification. Conclusion: Fluoroscopic-guided cystography for SEAC accurately demonstrates the presence and location of duraL defects. Preoperative digital subtraction cystography is useful for detection of a communicating hole between a cyst and the subarachnoid space.

키워드

Spinal extradural arachnoid cyst; Communicating hole; Cystography; Computed tomography myelography; Magnetic resonance imaging; MYELOGRAPHY
제목
Digital Subtraction Cystography for Detection of Communicating Holes of Spinal Extradural Arachnoid Cysts
저자
Gu, Kyowon; Kwon, Jong Won; Kim, Eun-Sang
DOI
10.3348/kjr.2016.17.1.111
발행일
2016-01
유형
Article
저널명
Korean Journal of Radiology
권
17
호
1
페이지
111 ~ 116