Low dose of contrast agent and low radiation liver computed tomography with deep-learning-based contrast boosting model in participants at high-risk for hepatocellular carcinoma: prospective, randomized, double-blind study

  • Kang, Hyo-Jin; 
  • Lee, Jeong Min; 
  • Ahn, Chulkyun; 
  • Bae, Jae Seok; 
  • Han, Seungchul; 
  • 외 3명
Citations

WEB OF SCIENCE

23
Citations

SCOPUS

24

초록

ObjectiveTo investigate the image quality and lesion conspicuity of a deep-learning-based contrast-boosting (DL-CB) algorithm on double-low-dose (DLD) CT of simultaneous reduction of radiation and contrast doses in participants at high-risk for hepatocellular carcinoma (HCC).MethodsParticipants were recruited and underwent four-phase dynamic CT (NCT04722120). They were randomly assigned to either standard-dose (SD) or DLD protocol. All CT images were initially reconstructed using iterative reconstruction, and the images of the DLD protocol were further processed using the DL-CB algorithm (DLD-DL). The primary endpoint was the contrast-to-noise ratio (CNR), the secondary endpoint was qualitative image quality (noise, hepatic lesion, and vessel conspicuity), and the tertiary endpoint was lesion detection rate. The t-test or repeated measures analysis of variance was used for analysis.ResultsSixty-eight participants with 57 focal liver lesions were enrolled (20 with HCC and 37 with benign findings). The DLD protocol had a 19.8% lower radiation dose (DLP, 855.1 +/- 254.8 mGy center dot cm vs. 713.3 +/- 94.6 mGy center dot cm, p = .003) and 27% lower contrast dose (106.9 +/- 15.0 mL vs. 77.9 +/- 9.4 mL, p < .001) than the SD protocol. The comparative analysis demonstrated that CNR (p < .001) and portal vein conspicuity (p = .002) were significantly higher in the DLD-DL than in the SD protocol. There was no significant difference in lesion detection rate for all lesions (82.7% vs. 73.3%, p = .140) and HCCs (75.7% vs. 70.4%, p = .644) between the SD protocol and DLD-DL.ConclusionsDL-CB on double-low-dose CT provided improved CNR of the aorta and portal vein without significant impairment of the detection rate of HCC compared to the standard-dose acquisition, even in participants at high risk for HCC.

키워드

Tomography; X-ray computed; Deep learning; Contrast media; Hepatocellular carcinoma; Prospective study; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT; THERAPY
제목
Low dose of contrast agent and low radiation liver computed tomography with deep-learning-based contrast boosting model in participants at high-risk for hepatocellular carcinoma: prospective, randomized, double-blind study
저자
Kang, Hyo-Jin; Lee, Jeong Min; Ahn, Chulkyun; Bae, Jae Seok; Han, Seungchul; Kim, Se Woo; Yoon, Jeong Hee; Han, Joon Koo
DOI
10.1007/s00330-023-09520-4
발행일
2023-05
유형
Article
저널명
European Radiology
권
33
호
5
페이지
3660 ~ 3670