상세 보기
Adenoma Characterization: Adrenal Protocol with Dual-Energy CT
- Kim, Yi Kyung;
- Park, Byung Kwan;
- Kim, Chan Kyo;
- Park, Sung Yoon
WEB OF SCIENCE
69SCOPUS
85초록
Purpose: To determine the diagnostic performance of dual-energy computed tomography (CT) by using virtual unenhanced CT to characterize adrenal masses. Materials and Methods: This study is retrospective, HIPAA-compliant, and approved by the institutional review board. Between December 2009 and June 2010, 49 patients with 49 adrenal masses underwent 120-kVp unenhanced CT and 80-kVp and 140-kVp early and delayed contrast agent-enhanced dual-energy CT. Early virtual unenhanced (EVU) and delayed virtual unenhanced (DVU) CT images were composed of data sets of early and delayed contrast-enhanced CT, respectively. Adenomas were divided into lipid-rich adenoma and lipid-poor adenoma on the basis of lesion attenuation values measured according to unenhanced CT and percentage loss of enhancement. Absolute percentage loss of enhancement was calculated with the following equation: (CTEE = CTDE) x 100/(CTEE = CTUE), where CTUE, CTEE, and CTDE are adrenal mass attenuation values at unenhanced CT, early contrast-enhanced CT, and delayed contrast-enhanced CT, respectively. The sensitivity of adrenal protocol adenoma with delayed contrast-enhanced CT was obtained with a reference standard of unenhanced CT, pathologic examination, or size stability on follow-up examination findings. Lesion attenuation values measured on unenhanced CT, EVU CT, and DVU CT images were compared by using repeated measures analysis of variance with post hoc test. Results: Of 49 masses, 33 were adenomas and 16 were nonadenomas. Adenoma group was 18 lipid-rich adenomas and 15 lipid-poor adenomas. Mean attenuation values of the lipidrich adenomas on EVU CT images (11.7 HU +/- 9.5) were significantly greater than those on unenhanced CT images (0.7 HU +/- 7.2) (P = .001) and DVU CT images (6.6 HU +/- 8.4) (P = .01). The sensitivities of EVU CT and DVU CT for lipid-rich adenoma were 39% (seven of 18) and 61% (11 of 18), respectively. The sensitivity for adenoma with percentage loss of enhancement values calculated from virtual unenhanced CT and early and delayed contrastenhanced CT was 100% (33 of 33). Conclusion: Although adrenal protocol with dual-energy CT by using virtual unenhanced CT and washout rate can help diagnose all lipid-poor adenomas, it may miss lipid-rich adenomas that can be diagnosed on unenhanced CT images. (C)RSNA, 2013
키워드
- 제목
- Adenoma Characterization: Adrenal Protocol with Dual-Energy CT
- 저자
- Kim, Yi Kyung; Park, Byung Kwan; Kim, Chan Kyo; Park, Sung Yoon
- 발행일
- 2013-04
- 유형
- Article
- 저널명
- Radiology
- 권
- 267
- 호
- 1
- 페이지
- 155 ~ 163
- 언어
- ENG
- 출판사
- Radiological Society of North America
- 발행국가
- 미국
- 분량
- 9 페이지
- ISSN
- E 1527-1315
P 0033-8419