Femoral versus jugular access for Denali Vena Cava Filter placement: Analysis of fluoroscopic time, filter tilt and retrieval outcomes

  • Choi, Sun-Ju; 
  • Lee, Sang Yub; 
  • Ryeom, Hun Kyu; 
  • Kim, Gab Chul; 
  • Lim, Jae-Kwang; 
  • 외 2명
Citations

WEB OF SCIENCE

10
Citations

SCOPUS

11

초록

Purpose: To analyze relevant metrics involved in Denali Vena Cava Filter placement via different venous access sites. Materials and methods: Patients with Denali filters inserted between March 2017 and February 2018 were retrospectively analyzed. Pre-procedural and pre-retrieval computed tomography (CT) were reviewed. We compared inferior vena cava (IVC) diameter, filter tilt angle, filter tip IVC wall abutment, fluoroscopy time, and retrieval outcomes by venous access site. Filter tip abutment/limb penetration and procedure-related complications were investigated. Results: Seventy-eight patients had successfully-placed Denali filters. Seventy-one of 78 (91%) patients had both pre-procedural and pre-retrieval CT. The majority (35 [49%]) were placed via the right femoral vein (left femoral vein: 22 [31%]; right internal jugular vein: 14 [20%]). The jugular approach involved a longer fluoroscopy time (mean 117 +/- 37s [s]) than the right and left femoral approaches (mean 64 +/- 21s, mean 67 +/- 15 s, respectively [p < 0.05]). Filter tilt and filter tip abutment were not significantly different between the 3 access routes. Filter tip abutment and limb penetration were observed in 8/71 (11%) and 2/71 (3%) patients, respectively. Filter retrieval was attempted in 68 of 78 (87%) cases, and all filters were successfully retrieved. One filter arm fractured during advanced retrieval; no other procedure related complications were recorded. Conclusions: Both femoral venous approaches can be safely used for placement of the Denali filter. Femoral venous access involved a shorter fluoroscopy time without any differences in filter tilt and filter tip abutment compared to transjugular access.

키워드

Inferior vena cava filter; Access site; Femoral; Radiation exposure; Procedure time; INTRODUCER CURVING TECHNIQUE; OPERATOR RADIATION-EXPOSURE; GUNTHER TULIP; COMPLICATIONS; CELECT; PREVENTION; EXPERIENCE; IVC
제목
Femoral versus jugular access for Denali Vena Cava Filter placement: Analysis of fluoroscopic time, filter tilt and retrieval outcomes
저자
Choi, Sun-Ju; Lee, Sang Yub; Ryeom, Hun Kyu; Kim, Gab Chul; Lim, Jae-Kwang; Lee, So Mi; Kim, Won Hwa
DOI
10.1016/j.clinimag.2018.09.008
발행일
2018-11
유형
Article
저널명
Clinical Imaging
권
52
페이지
337 ~ 342