Effects of balloon-based distal protection during primary percutaneous coronary intervention on early and late infarct size and left ventricular remodeling: A pilot study using serial contrast-enhanced magnetic resonance imaging

Citations

WEB OF SCIENCE

60
Citations

SCOPUS

21

초록

Background Distal protection devices are effective in preventing distal embolization during primary percutaneous coronary intervention (PCI). We investigated whether balloon-based distal protection could reduce early and late infarct size and left ventricular (LV) remodeling using serial analysis of contrast-enhanced magnetic resonance imaging (CE-MRI). Methods Patients undergoing primary PCI for ST-segment elevation myocardial infarction within 12 hours after symptom onset were randomized to a distal protection group (n = 19) or to a control group (n = 20). The primary end point was infarct size evaluated by the volume of delayed hyperenhancement on CE-MRI at 3 days. The secondary end point included infarct size on CE-MRI at 6 months and LV remodeling assessed by the change between LV end-diastolic volume on CE-MRI at 3 days (baseline) and 6 months (follow-up). Results Percutaneous coronary intervention procedures were fully protected with balloon-based distal protection in all patients of the protection group. Infarct size was similar in the distal protection group and the control group at baseline (25.9 +/- 7.8% vs 26.1 +/- 8.2%; P =.93) and at follow-up (21.4 +/- 9.1% vs 18.5 +/- 9.1%; P =.51). The change in LV end-diastolic volume was 10.5 +/- 32.2 mL in the distal protection group and 8.9 +/- 40.7 mL in the control group (P =.86). There was no significant difference in the 6-month rate of major adverse cardiac events between groups (none in the distal protection group and A patients in the control group; P =.11). Conclusions Serial CE-MRI showed that the balloon-based distal protection during primary PCI did not reduce early and late infarct size or prevent LV remodeling.

키워드

ACUTE MYOCARDIAL-INFARCTION; ST-SEGMENT ELEVATION; PRIMARY ANGIOPLASTY; PERFUSION; INJURY; MRI; REPERFUSION; MORTALITY; OCCLUSION; DEVICE
제목
Effects of balloon-based distal protection during primary percutaneous coronary intervention on early and late infarct size and left ventricular remodeling: A pilot study using serial contrast-enhanced magnetic resonance imaging
저자
Hahn, Joo-Yong; Gwon, Hyeon-Cheol; Choe, Yeon Hyeon; Rhee, Il; Choi, Seung Hyuk; Choi, Jin Ho; Lee, Sang Hoon; Hong, Kyong Pyo; Park, Jung Euy
DOI
10.1016/j.ahj.2007.01.031
발행일
2007-04
유형
Article
저널명
American Heart Journal
권
153
호
4
페이지
665.e1 ~ 665.e8