Risk factors of radiation dose in patients undergoing peripherally-inserted central catheter procedure using conventional angiography equipment and flat panel detector-based mobile C-arm fluoroscopy

Citations

WEB OF SCIENCE

6
Citations

SCOPUS

9

초록

Background Although peripherally-inserted central catheter (PICC) insertion is commonly performed under fluoroscopic guidance, few reports have addressed performance and dosimetry when PICC is inserted under C-arm fluoroscopy. Purpose To evaluate the risk factors of radiation dose in performing PICC insertion using flat panel detector-based mobile C-arm fluoroscopy and a conventional angiography machine. Material and Methods Ninety-eight patients underwent the PICC procedure using conventional angiography equipment (n=49) or flat panel detector-based mobile C-arm fluoroscopy (n=49). Data were prospectively analyzed from July to November 2012. Dose-area product (DAP), tube voltage, tube current, fluoroscopy time, and image quality measured on a 5-point scale were estimated and compared using appropriate statistical tests. Results There were no significant differences in tube voltage, fluoroscopy time, and image quality between conventional angiography and mobile C-arm fluoroscopy. DAP, mean arm tube current, and tube current in chest fluoroscopy were significantly lower in mobile C-arm fluoroscopy than using the conventional angiography machine (P<0.05). Multivariate analysis identified tube current in chest fluoroscopy, arm tube current, and fluoroscopy equipment as significant risk factors for elevated radiation dose in PICC insertion. Conclusion PICC insertion can be performed using flat panel detector-based mobile C-arm fluoroscopy instead of a conventional angiography machine. Image quality and fluoroscopy time were not different between the two systems and the use of C-arm fluoroscopy significantly reduced radiation dose.

키워드

Peripherally-inserted central catheter; mobile C-arm fluoroscopy; angiography; dose-area product; radiation dose; INTERVENTIONAL CARDIOLOGY; ITERATIVE RECONSTRUCTION; TUBE VOLTAGE; RADIOLOGY
제목
Risk factors of radiation dose in patients undergoing peripherally-inserted central catheter procedure using conventional angiography equipment and flat panel detector-based mobile C-arm fluoroscopy
저자
Lee, TaeBum; Shin, Sung Wook; Choi, Dongil; Cho, Sung Ki; Hyun, Dongho; Do, Young Soo; Jeon, SungChae; Cha, BoKyung; Bok, Eun Kyung; Kim, Seonwoo
DOI
10.1177/0284185113514221
발행일
2014-12
유형
Article
저널명
Acta Radiologica
권
55
호
10
페이지
1234 ~ 1238