Association of pre-transplant torque teno virus load with early post-transplant outcomes in lung transplant recipients: A multicenter cohort study

  • Lee, HyunJi; 
  • Cho, Woo Hyun; 
  • Kim, Kipoong; 
  • Kim, A. Reum; 
  • Oh, Seung-Hwan; 
  • ... Jeon, Kyeongman; 
  • 외 5명
Citations

WEB OF SCIENCE

2
Citations

SCOPUS

2

초록

Background Torque teno virus (TTV) load has emerged as a potential surrogate marker of net immunosuppression in solid organ transplantation. However, the clinical significance of pre-transplant TTV levels for early outcomes after lung transplantation remains unclear. Methods In this multicenter cohort of 334 adult first-time lung transplant recipients (2015-2022), plasma samples were collected immediately prior to transplantation. The primary endpoint was infection within 3 months. One hundred healthy individuals served as controls for TTV comparisons. Secondary outcomes were acute rejection and 1-year graft failure. Associations were evaluated using multivariable logistic regression for early infection and time-to-event analyses for rejection and graft failure. Results Pre-transplant TTV levels were higher in recipients than in controls (6.7 vs 5.9 log(1)(0) copies/mL; p<0.001). Early infections occurred in 103 patients (30.8%). Patients with infection had higher pre-transplant TTV levels than those without infection (7.8 vs 6.3 log(1)(0) copies/mL; p<0.001). Each 1-log(1)(0) increase in TTV was associated with higher infection risk (adjusted odds ratio 15.05; 95% CI 7.25-31.20; p<0.001). Receiver operating characteristic analysis showed good discrimination for identifying early infection (AUC 0.89; 95% CI 0.85-0.92). Higher TTV levels were associated with lower acute rejection risk (adjusted hazard ratio 0.70; 95% CI 0.56-0.87; p = 0.001) and higher 1-year graft failure (adjusted hazard ratio 1.40; 95% CI 1.13-1.74; p = 0.002). Conclusions Pre-transplant plasma TTV load was associated with early infection, fewer rejection events, and increased 1-year graft failure after lung transplantation, supporting its potential role as a biomarker for immune risk stratification. (c) 2026 The Authors. Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation. This is an open access article under the CC BY license (http://creativecommons.org/ licenses/by/4.0/).

키워드

lung transplantation; torque teno virus; infection; graft failure; rejection; biomarker; CLINICAL-PRACTICE GUIDELINES; INFECTIOUS-DISEASES SOCIETY; INTERNATIONAL SOCIETY; ADULT LUNG; WORKING FORMULATION; HEART; DIAGNOSIS; REGISTRY; UPDATE; STANDARDIZATION
제목
Association of pre-transplant torque teno virus load with early post-transplant outcomes in lung transplant recipients: A multicenter cohort study
저자
Lee, HyunJi; Cho, Woo Hyun; Kim, Kipoong; Kim, A. Reum; Oh, Seung-Hwan; Lee, Jin Gu; Kim, Song Yee; Park, Samina; Jeon, Kyeongman; Hong, Hanpyo; Yeo, Hye Ju
DOI
10.1016/j.healun.2026.03.017
발행일
2026-08
유형
Article
저널명
Journal of Heart and Lung Transplantation
권
45
호
8
페이지
1322 ~ 1331