상세 보기
A Bottom-Up Liquid Chromatography-Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Infliximab Method Development, Comparison With 2 Enzyme-Linked Immunosorbent Assay Methods, and Evaluation of Anti-Drug Antibody Interference
- Kim, Sang-Mi;
- Oh, Hyeonju;
- Hong, Sung Noh;
- Kim, Mi Jin;
- Choe, Yon Ho;
- ... Lee, Soo-Youn
WEB OF SCIENCE
2SCOPUS
2초록
center dot Context.-Therapeutic drug monitoring is recommended to optimize infliximab use and improve outcome in chronic inflammatory disorders. Objective.-To describe a simple and affordable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to measure infliximab in serum. Design.-Infliximab was measured using winged stable isotope-labeled peptides as internal standards. Linearity, lower limit of measuring interval, limit of detection, precision, accuracy, carryover, and ion suppression were evaluated. Method comparison against 2 enzyme-linked immunosorbent assay (ELISA) methods (Remsima Monitor and IDKmonitor Infliximab) and anti-drug antibody (ADA) interference were evaluated using clinical specimens from inflammatory bowel disease patients (N = 237). Results.-Analytical run time and sample preparation time were 5 minutes per sample and 3 hours per batch, respectively. Analytical measurement interval and limit of detection were 0.50 to 50.0 lg/mL (R2 = 0.998) and 0.25 lg/mL, respectively. The intraday and interday imprecision percentage coefficients of variation were less than 6.1%. Accuracy was 94.2% to 98.7%. No significant ion suppression or carryover was observed. Infliximab concentrations measured by LC-MS/MS showed good agreement with those measured by Remsima Monitor (mean percentage difference, 5.7%; 95% CI,-1.2% to 12.6%) but were markedly lower than those measured by IDKmonitor (-32.6%;-35.8% to-29.4%), demonstrating significant bias between ELISAs. Although a good agreement between LC-MS/MS and ELISA was observed for ADA-negative samples (-3.5%;-12.8% to 5.9%), a significant bias was observed for ADA-positive samples (13.6%; 1.7% to 25.6%). Conclusions.-This simple, fast, and affordable LC-MS/ MS method for infliximab quantitation could improve standardization of infliximab quantitation and optimization of infliximab use in patients with high-titer ADA.
키워드
- 제목
- A Bottom-Up Liquid Chromatography-Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Infliximab Method Development, Comparison With 2 Enzyme-Linked Immunosorbent Assay Methods, and Evaluation of Anti-Drug Antibody Interference
- 저자
- Kim, Sang-Mi; Oh, Hyeonju; Hong, Sung Noh; Kim, Mi Jin; Choe, Yon Ho; Lee, Soo-Youn
- 발행일
- 2025-05
- 유형
- Article
- 권
- 149
- 호
- 5
- 페이지
- 448 ~ 456
- 언어
- ENG
- 출판사
- American Medical Association
- 발행국가
- 미국
- 분량
- 9 페이지
- ISSN
- E 1543-2165
P 0003-9985