The dependency of beam-on-time efficiency on respiration period and layer switching time for respiratory gating proton therapy of liver cancer

Citations

WEB OF SCIENCE

3

초록

Background: Patient's respiratory motion can significantly affect the treatment accuracy and efficiency of radiotherapy, making effective respiratory control essential. One option is respiratory gating therapy, which allows treatment only during specific phases of the respiratory cycle but typically increases treatment time. Therefore, optimizing beam-on-time (BoT) efficiency in respiratory gating therapy is needed. Purpose: This study examines the BoT efficiency of respiratory gating proton line-scanning therapy for liver cancer patients, with the aim of minimizing treatment time. Methods: We calculated the BoT of proton beams for 101 liver cancer patients, by using a simulated respiratory signal. BoT efficiency was defined as the ratio of BoT to the total treatment time, which is the sum of BoT, layer switching times (T-LS) and gating-off times for each layer. We varied three parameters to measure their effect on BoT efficiency: respiratory period (T-R), T-LS, and gating window level. Results: We observed that BoT efficiency reached a maximum at a specific respiratory period, T-R(M), that showed a linear correlation with T-LS. With very short T-LS values, BoT efficiency did not vary with changes in T-R. However, when T-LS exceeded 1 s, the respiratory period that yielded peak BoT efficiency, T-R(M), was closely aligned with T-LS. Furthermore, this alignment displays a slope close to 1. By comparing results across different simulated respiratory signals, we found our conclusions were insensitive to the specific shape of the respiratory signal. Conclusions: This study presents two key strategies for reducing total treatment time: (1) for the proton therapy machine with very short T-LS, BoT efficiency is less of a concern; and (2) for machines with a T-LS of around 2 s, optimal BoT efficiency is achieved with a respiration period between 2.5 and 3 s. It is important to note that the exact optimal value may vary depending on patient-specific factors such as target size.

키워드

beam-on-time efficiency; intensity-modulated proton therapy; liver cancer; HEPATOCELLULAR-CARCINOMA; RADIATION ONCOLOGY; RADIOTHERAPY; PARAMETERS; MANAGEMENT; CONSENSUS; PATIENT; IMPACT
제목
The dependency of beam-on-time efficiency on respiration period and layer switching time for respiratory gating proton therapy of liver cancer
저자
Jo, Kwanghyun; Jang, Junyoung; Ahn, Seunghoon; Yoo, Gyu Sang; Yu, Jung Il; Cho, Sungkoo; Park, Hee Chul
DOI
10.1002/mp.17770
발행일
2025-06
유형
Article
저널명
Medical Physics
권
52
호
6
페이지
4883 ~ 4893