상세 보기
Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin
- Yoo, H. M.;
- Pereira, P. N. R.
WEB OF SCIENCE
31SCOPUS
41초록
This study evaluated the effect of blood contamination and decontamination methods on the microtensile bond strength of I-step self-etching adhesive systems to dentin contaminated after adhesive application and light curing. Three commercially available "all-in-one" adhesives (One Up Bond F, Xeno III and Adper Prompt L-Pop) and 1 resin composite (Clearfil AP-X) were used. Third molars that had been stored in distilled water with 0.5% thymol at 4 degrees C were ground with #600 SiC paper under running water to produce a standardized smear layer. The specimens were randomly divided into groups according to the 3 adhesive systems. The adhesive systems were used under 3 conditions: no contamination, which was the control (C); contamination of the light-cured adhesive surface with blood and reapplication of adhesive (Contamination 1) and contamination of the light-cured adhesive surface with blood, then washing, drying and reapplication of the adhesive (Contamination 2). Following light curing of the adhesive, the resin composite was placed in 3 increments up to a 5-mm-thick layer on the bonded surface. All specimens were stored in distilled water at 37 degrees C for 24 hours. The microtensile bond strength was measured using a universal testing machine (EZ test), and data were analyzed by 1-way ANOVA followed by the Duncan test to make comparisons among the groups (p=0.05). After debonding, 5 specimens were selected from each group and examined in a scanning electron microscope to evaluate the modes of fracture. For all adhesives, contamination groups showed lower bond strength than the control (p<0.05). There was no statistically significant difference among the control groups (p>0.05). For Xeno III and Adper Prompt L-Pop, contamination group #2 showed the lowest bond strength among the groups (p<0.05). For One Up Bond F, contamination group #2 showed higher bond strength than contamination group #1 but showed no statistical significance between them (p>0.05).
키워드
- 제목
- Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin
- 저자
- Yoo, H. M.; Pereira, P. N. R.
- DOI
- 10.2341/05-1279
- 발행일
- 2006-11
- 유형
- Article
- 권
- 31
- 호
- 6
- 페이지
- 660 ~ 665
- 언어
- ENG
- 출판사
- IU School of Dentistry
- 발행국가
- 인도
- 분량
- 6 페이지
- ISSN
- E 1559-2863
P 0361-7734