Comparison of Different Time of Flight-Mass Spectrometry Modes for Small Molecule Quantitative Analysis

Citations

WEB OF SCIENCE

23
Citations

SCOPUS

26

초록

Currently, the use of time of flight (TOF)-mass spectrometry (MS) in quantitative analysis of small molecules is rare. Recently, the quantitative performance of TOF mass analyzers has improved due to the advancements in TOF technology. We evaluated a Q-TOF-MS in different modes, i.e., Q-TOF-full scan (Q-TOF-FS), Q-TOF-enhanced-full scan (Q-TOF-En-FS), MSE, Q-TOF-targeted (Q-TOF-TGT), Q-TOF-enhanced-targeted (Q-TOF-En-TGT), and compared their quantitative performance against a unit resolution LC-MS-MS (tandem quadrupole) platform. The five modes were investigated for sensitivity, linearity, signal-to-noise ratio, recovery and precision using 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH) as a model compound in electrospray ionization (ESI) with negative polarity. Preliminary studies indicated that Q-TOF-FS mode was the least linear and precise; hence, it was eliminated from further investigation. Total imprecision in remaining four modes was < 10%. The Q-TOF-En-FS and Q-TOF-En-TGT showed better signal intensity than their respective modes without enhancement. Overall, peak signal intensity was the highest in MSE mode, whereas the signal-to-noise ratio was the best in the Q-TOF-En-TGT mode. Relatively, MSE and Q-TOF-En-TGT modes were the best overall performers compared with the other modes. Both MSE and Q-TOF-En-TGT modes showed excellent precision (coefficient of variation <6%), patient correlation (r > 0.99) and linearity (range, 52455 ng/mL) for THC-COOH analysis when compared with LC-MS-MS. We also investigated the performance of the same four modes using methamphetamine in positive ESI. Quantitative data obtained by Q-TOF-En-TGT and MSE, using both positive and negative ESI, suggest that these modes performed better than the other modes. While unit resolution LC-MS-MS remains the optimal technique for quantification, our data showed that Q-TOF-MS can also be used to quantify small molecules in complex biological specimens.

키워드

UPLC-TOF-MS; VETERINARY DRUGS; QUANTIFICATION; PERFORMANCE; DELTA(9)-TETRAHYDROCANNABINOL; METABOLITES; EXTRACTION; TOXICOLOGY; SAMPLES; BLOOD
제목
Comparison of Different Time of Flight-Mass Spectrometry Modes for Small Molecule Quantitative Analysis
저자
Chindarkar, Nandkishor S.; Park, Hyung-Doo; Stone, Judith A.; Fitzgerald, Robert L.
DOI
10.1093/jat/bkv057
발행일
2015-11
유형
Article
저널명
Journal of Analytical Toxicology
권
39
호
9
페이지
675 ~ 685