상세 보기
Spatial Normalization Using Early-Phase [18F]FP-CIT PET for Quantification of Striatal Dopamine Transporter Binding
- Bae, Sungwoo;
- Choi, Hongyoon;
- Whi, Wonseok;
- Paeng, Jin Chul;
- Cheon, Gi Jeong;
- 외 2명
초록
OBJECTIVE: The precise quantification of dopamine transporter (DAT) density on N-(3-[18F]Fluoropropyl)-2β-carbomethoxy-3β-(4-iodophenyl) nortropane positron emission tomography ([18F]FP-CIT PET) imaging is crucial to measure the degree of striatal DAT loss in patients with parkinsonism. The quantitative analysis requires a spatial normalization process based on a template brain. Since the spatial normalization method based on a delayed-phase PET has limited performance, we suggest an early-phase PET-based method and compared its accuracy, referring to the MRI-based approach as a gold standard. METHODS: A total of 39 referred patients from the movement disorder clinic who underwent dual-phase [18F]FP-CIT PET and took MRI within 1 year were retrospectively analyzed. The three spatial normalization methods were applied for quantification of [18F]FP-CIT PET-MRI-based anatomical normalization, PET template-based method based on delayed PET, and that based on early PET. The striatal binding ratios (BRs) were compared, and voxelwise paired t tests were implemented between different methods. RESULTS: The early image-based normalization showed concordant patterns of putaminal [18F]FP-CIT binding with an MRI-based method. The BRs of the putamen from the MRI-based approach showed higher agreement with early image- than delayed image-based method as presented by Bland-Altman plots and intraclass correlation coefficients (early image-based, 0.980; delayed image-based, 0.895). The voxelwise test exhibited a smaller volume of significantly different counts in putamen between brains processed by early image and MRI compared to that between delayed image and MRI. CONCLUSIONS: The early-phase [18F]FP-CIT PET can be utilized for spatial normalization of delayed PET image when the MRI image is unavailable and presents better performance than the delayed template-based method in quantitation of putaminal binding ratio. © Korean Society of Nuclear Medicine 2020.
키워드
- 제목
- Spatial Normalization Using Early-Phase [18F]FP-CIT PET for Quantification of Striatal Dopamine Transporter Binding
- 저자
- Bae, Sungwoo; Choi, Hongyoon; Whi, Wonseok; Paeng, Jin Chul; Cheon, Gi Jeong; Kang, Keon Wook; Lee, Dong Soo
- 발행일
- 2020-12
- 유형
- Journal Article
- 권
- 54
- 호
- 6
- 페이지
- 305 ~ 314
- 언어
- ENG
- 발행국가
- 대한민국
- 분량
- 10 페이지
- ISSN
- E 1869-3482
P 1869-3474