상세 보기
Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT
- Jeong, YJ;
- Lee, KS;
- Jeong, SY;
- Chung, MJ;
- Shim, SS;
- 외 3명
WEB OF SCIENCE
132SCOPUS
154초록
PURPOSE: To prospectively assess the accuracy of combined wash-in and washout characteristics at dynamic contrast material-enhanced multi-detector row computed tomography (CT) in distinguishing benign from malignant solitary pulmonary nodules. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. The study included 107 patients (62 men, 45 women; mean age, 55 years; range, 22-81 years) with a solitary pulmonary nodule. After unenhanced CT (2.5-mm collimation) scans were obtained, dynamic CT was performed by using a helical technique (series of images obtained throughout the nodule, with 2.5-mm collimation, at 30, 60, 90, and, 120 seconds and 4, 5, 9, 12, and 15 minutes) after intravenous injection of contrast medium (1120 mL). Tissue diagnosis was made in 70 nodules, and follow-up images showed benignancy in the remaining 17 (no change in size, n = 32; decrease in size, n = 5). CT findings were analyzed in terms of wash-in and washout of contrast medium. Sensitivity, specificity, and accuracy for malignant nodules were calculated by considering both the wash-in and washout characteristics at dynamic CT. RESULTS: There were 49 malignant,land 58 benign nodules. When diagnostic criteria for malignancy of both wash-in of 25 HU or greater and washout of 5-31 HU were applied, sensitivity, specificity, and accuracy for malignancy were 94% (46 of 49 nodules), 90% (52 of 58 nodules), and 92% (98 of 107 nodules), respectively. Of 58 benign nodules, 27 showed less than 25 HU wash-in, 14 showed persistent contrast enhancement without washout and with wash-in of 25 HU or greater, and 11 showed washout greater than 31 HU and wash-in of 25 HU or greater. CONCLUSION: Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multi-detector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules. (c) RSNA, 2005.
키워드
- 제목
- Solitary pulmonary nodule: Characterization with combined wash-in and washout features at dynamic multi-detector row CT
- 저자
- Jeong, YJ; Lee, KS; Jeong, SY; Chung, MJ; Shim, SS; Kim, H; Kwon, OJ; Kim, S
- 발행일
- 2005-11
- 유형
- Article
- 저널명
- Radiology
- 권
- 237
- 호
- 2
- 페이지
- 675 ~ 683
- 언어
- ENG
- 출판사
- Radiological Society of North America
- 발행국가
- 미국
- 분량
- 9 페이지
- ISSN
- E 1527-1315
P 0033-8419