Comparative Evaluation Between the RealStar <i>Pneumocystis jirovecii</i> PCR Kit and the AmpliSens <i>Pneumocystis jirovecii </i>(<i>carinii</i>)-FRT PCR Kit for Detecting <i>P-jirovecii</i> in Non -HIV Immunocompromised Patients
- Huh, Hee Jae;
- Lim, Kyoung Ree;
- Ki, Chang-Seok;
- Huh, Kyungmin;
- Shim, Hyang Jin;
- ... Kim, Yae-Jean;
- ... Chung, Doo Ryeon;
- 외 2명
WEB OF SCIENCE
11SCOPUS
14초록
Background: Real-time PCR is more sensitive than microscopic examination for detecting Pneumocystis jirovecii. We compared the performance of two assays for detecting P. jirovecii DNA: the RealStar Pneumocystis jirovecii PCR Kit 1.0 CE (Altona Diagnostics, Hamburg, Germany) and the AmpliSens Pneumocystis jirovecii (carinii)-FRT PCR kit (InterLab-Service Ltd., Moscow, Russia). Methods: We used 159 samples from the lower respiratory tract (112 bronchoalveolar lavage [BAL] fluid, 37 sputum, and 10 endotracheal aspirate [ETA] samples) of non-HIV immunocompromised patients. Nested PCR and sequencing were used to resolve discordant results. The performance of the two assays was evaluated according to clinical categories (clinical Pneumocystis pneumonia [PCP], possible PCP, or unlikely PCP) based on clinical and radiological observations. Results: The positive and negative percent agreement values were 100% (95% confidence interval [CI], 85.4-100%) and 96.6% (95% CI, 90.9-98.9%), respectively, and kappa was 0.92 (95% CI, 0.84-0.99). P. jirovecii. DNA load was significantly higher in the clinical PCP group than in the other groups (P<0.05). When stratified by sample type, the positive rate for BAL fluids from the clinical PCP group was 100% using either assay, whereas the positive rate for sputum/ETA samples was only 20%. Conclusions: The two assays showed similar diagnostic performance and detected low P. jirovecii burden in BAL fluids. Both assays may be useful as routine methods for detecting P. jirovecii DNA in a clinical laboratory setting, though their results should be interpreted considering sample type.
키워드
- 제목
- Comparative Evaluation Between the RealStar <i>Pneumocystis jirovecii</i> PCR Kit and the AmpliSens <i>Pneumocystis jirovecii </i>(<i>carinii</i>)-FRT PCR Kit for Detecting <i>P-jirovecii</i> in Non -HIV Immunocompromised Patients
- 저자
- Huh, Hee Jae; Lim, Kyoung Ree; Ki, Chang-Seok; Huh, Kyungmin; Shim, Hyang Jin; Song, Dong Joon; Kim, Yae-Jean; Chung, Doo Ryeon; Lee, Nam Yong
- 발행일
- 2019-03
- 유형
- Article
- 권
- 39
- 호
- 2
- 페이지
- 176 ~ 182
- 언어
- ENG
- 출판사
- 대한진단검사의학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- E 2234-3814
P 2234-3806