Open surgery for removal of a failing Gianturco stent with reversed sleeve resection of the right middle and lower lobes

  • Kim, J; 
  • Kim, H; 
  • Kim, K; 
  • Shim, YM
Citations

WEB OF SCIENCE

2
Citations

SCOPUS

1

초록

Although the use of a metallic stent in the treatment of benign tracheobronchial stenosis has been reported as a useful and safe technique, the incorporation of wire stents into the airway may be irreversible and is associated with problems. The authors' experience in a patient with incorrectly positioned metallic stent in the right main bronchus, which was successfully treated with bronchial sleeve resection, is presented. (C) 1998 Elsevier Science B.V. All rights reserved.

키워드

Gianturco expandable metal stent; incorrect position; bronchial sleeve resection; BRONCHIAL STENOSIS
제목
Open surgery for removal of a failing Gianturco stent with reversed sleeve resection of the right middle and lower lobes
저자
Kim, J; Kim, H; Kim, K; Shim, YM
DOI
10.1016/S1010-7940(98)00195-X
발행일
1998-09
유형
Article
저널명
European Journal of Cardio-thoracic Surgery
권
14
호
3
페이지
329 ~ 331