CFD modeling of blood flow following coil embolization of aneurysms

  • Byun, HS; 
  • Rhee, K
Citations

WEB OF SCIENCE

47
Citations

SCOPUS

62

초록

In case of coil embolization of a giant or a multilobular aneurysm, it is difficult to fill an aneurysm sac completely with coils, therefore, partial blocking of an aneurysm sac is inevitable. Blood flow characteristics, which may influence embolization process of an aneurysm, are affected by the locations of coils for partially blocked aneurysms. Blood flow fields inside an aneurysm are also influenced by the geometry of a parent vessel. In order to suggest the coil locations effective for aneurysm embolization, the blood flow fields of lateral aneurysm models were analyzed for different coil locations and parent vessel geometries. Flow rate into an aneurysm sac from a parent vessel (inflow rate) and wall shear stress were also calculated. Inflow rates were smaller and low wall shear regions were larger in the distal neck blocked model comparing to the dome blocked models. In the distal neck blocked model, inflow volume was smaller by 31% (straight parent vessel model) and 34% (curved parent vessel model) comparing to other models. The time averaged values of normalized low wall shear regions were 4% and 12% greater in the distal neck blocked models with a straight and a curved parent vessel, respectively. Since smaller inflow and low wall shear stress provide hemodynamic environment promoting thrombus embolization, distal neck should be the effective coil location for aneurysm embolization. (C) 2004 IPEM. Published by Elsevier Ltd. All rights reserved.

키워드

coil embolization; lateral aneurysm; hemodynamics; numerical analysis; STAGNATION POINT FLOW; PLATELET-ADHESION; FLUID-MECHANICS; DYNAMICS; DEPOSITION; VESSEL
제목
CFD modeling of blood flow following coil embolization of aneurysms
저자
Byun, HS; Rhee, K
DOI
10.1016/j.medengphy.2004.06.008
발행일
2004-11
유형
Article
저널명
Medical Engineering & Physics
권
26
호
9
페이지
755 ~ 761