Removal of a femoral interference screw that migrated posteriorly, using a posterior trans-septal portal: a case report

  • Ahn, Jin Hwan; 
  • Lee, Sang Hak; 
  • Ha, Hae Chan
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Few cases have been reported in which the femoral interference screw has migrated into the posterior compartment after an ACL reconstruction. It usually requires removal, because it leads usually to mechanical symptom. However, the arthroscopic removal of a screw is a technically demanding procedure, especially in the case of the femoral interference screw that has migrated into the femoral notch (posterior compartment), an intact integrated ACL graft or one that is encapsulated around the screw. We present a case in which a displaced femoral interference screw migrated within the posterior compartment 11 years postoperatively, after the graft had been incorporated at the femoral site. Although it is often technically challenging, through the use of a posterior trans-septal portal, we can successfully remove a displaced femoral interference screw even in the most difficult locations in the posterior compartment.

키워드

anterior cruciate ligament reconstruction; femoral interference screw; migrated posteriorly; posterior trans-septal portal; LIGAMENT; GRAFT
제목
Removal of a femoral interference screw that migrated posteriorly, using a posterior trans-septal portal: a case report
저자
Ahn, Jin Hwan; Lee, Sang Hak; Ha, Hae Chan
DOI
10.1007/s00167-006-0212-9
발행일
2007-05
유형
Article
저널명
Knee Surgery, Sports Traumatology, Arthroscopy
권
15
호
5
페이지
569 ~ 572