Accuracy of a proposed implant impression technique using abutments and metal framework

  • Lee, Hyeok-Jae .; 
  • Lim, Young-Jun; 
  • Kim, Chang-Whe; 
  • Choi, Jung-Han; 
  • Kim, Myung-Joo
Citations

WEB OF SCIENCE

11
Citations

SCOPUS

16

초록

PURPOSE. This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cement-on crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS. Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test. RESULTS. The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05). CONCLUSION. The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.

키워드

Implant; Abutment; Metal framework; Vertical gap; Angulation; SUPPORTED PROSTHESES; CAST
제목
Accuracy of a proposed implant impression technique using abutments and metal framework
저자
Lee, Hyeok-Jae .; Lim, Young-Jun; Kim, Chang-Whe; Choi, Jung-Han; Kim, Myung-Joo
DOI
10.4047/jap.2010.2.1.25
발행일
2010-03
유형
Article
저널명
Journal of Advanced Prosthodontics
권
2
호
1
페이지